Alat SMK 2018 -KOMPETENSI KEAHLIAN TEKNIK INSTALASI TENAGA LISTRIK - Alat Praktek SMK TEKNIK INSTALASI TENAGA LISTRIK 2018


KOMPETENSI KEAHLIAN TEKNIK INSTALASI TENAGA LISTRIK               
               
No    Nama Peralatan    Merk    Tipe    Harga Satuan
1    Electrical Maintenance Skill Training Workbench    CHOIEO    66962701     359.691.000
2    Basic Electric Training System    CHOIEO    66962203     77.775.000
3    Electricity Protection Training System    SSEDU    ZE3104     145.906.500
4    Low and Middle Voltage Simuation Training System    CHOIEO    66962120     93.762.000
5    Frequency Control Speed Regulation Experiment System    CHOIEO    66962602     122.055.000
6    Programmable Logic Controller Training Set    CHOIEO    66965101     112.602.000
7    Servo Motor Trainer    XINGKE    XK-DCSF2     25.375.500
8    Step Motor Training Set    XINGKE    XK821     22.204.500
9    Electrical Installation Training System     CHOIEO    66962200     84.309.000
10    Multi Function Measuring Instrument System    YES01    YESA-7000     615.598.500
Alat SMK 2018 ,KOMPETENSI KEAHLIAN TEKNIK INSTALASI TENAGA LISTRIK  ,Alat Praktek SMK TEKNIK INSTALASI TENAGA LISTRIK  2018,jual alat peraga smk,grosir alat praktek smk,produksi alat praktek smk 2018,dak smk 2018,dak smk 2019

KOMPETENSI KEAHLIAN TEKNIK AUDIO VIDEO                   
                   
No    Nama Peralatan    Spesifikasi           
1    Electrical Maintenance Skill Training Workbench    Features :           
        • Electrical installation and maintenance trainer is a common training platform that is developed to meet the maintenance electrician and electrical installer skills training requirements.           
        • It is made of steel meshed plate and steel dedicated sectional material and equipped with self-locking truckles, which is convenient for moving and usage. The surface of trainer is plastics sprayed, the design height is convenient for operation that students can feel the environment of construction site by standing on level 1 of the ladder, which is safe and effective.            
        • The meshed plate can be stripped easily, the steel dedicated sectional material is designed with pipe hole that by using ribbon can fix the wire and pipe fixed on it. Equipped with PVC pipe bender, the PVC pipe can be bent into 90°.            
        • It covers training content such as cable tray installation , PVC pipe installation , droplight, incandescent seat, fluorescent lamp, switches, sockets, distribution box, control box installation, etc. The control and controlled plant adopted for this trainer including AC asynchronous motor, DC motor, stepper motor, servo motor, temperature controller, galvanic couple, PLC, frequency converter, touch screen and so on. Each operation group is equipped with movable tool car and component cabinet, which convenient for component storage and construction.            
        • Safety protections: grounded, lead protection, safety in accordance with related standards. Overcurrent, overload, earth leakage protection function.            
        TRAINING CONTENT            
        • Meter box installation
           
        • Distribution box installation
           
        • Fluorescent lamp installation
           
        • Incandescent light installation
           
        • Ceiling lamp installation
           
        • Energy saving lamp installation
           
        • High pressure sodium lamp installation            
        • PVC pipe processing and layout
           
        • PVC pipe threading
           
        • Switch and socket installation            
        • Junction box installation
           
        • Line distribution design
           
        • Construction specifications learning and training            
        • Construction safety requirements learning and training            
        • Remote and local control of one lamp
           
        • Trunking wiring construction training
           
        • Concealed work construction training            
        • Disconnecting switch installation            
        • Distribution line wiring training            
        1). Metal bridge combination and installation training            
        2). Plastic trunking laying training
           
        3). Metal line pipe laying training            
        • Electrical control box installation
           
        • Electrical control circuit installation training            
        1). Three phase asynchronous motor direct starting, parking control circuit connection
           
        2). Contactor interlocked three-phase AC asynchronous motor forward and reverse control circuit connection
           
        3). Button interlocked three-phase AC asynchronous motor forward and reverse control circuit connection
           
        4). Button, contactor interlocked three-phase AC asynchronous motor forward and reverse control circuit connection            
        5). Three-phase AC asynchronous motor Y-∆ (manual switch) starting control circuit connection
           
        6). Three-phase AC asynchronous motor Y-∆ (time relay switch) starting control circuit connection
           
        7). Stator winding series resistance starting control circuit connection
           
        8). Three-phase AC asynchronous motor energy consumption braking control circuit connection
           
        9). Three-phase AC asynchronous motor reverse braking control circuit connection
           
        10). Motor sequential control circuit connection (Qty≤3)
           
        11). Motor round trip control circuit connection
           
        12). Center lathe control circuit connection
           
        13). Electric block control circuit connection
           
        14). Three-phase AC asynchronous motor inching and continuous rotation control circuit connection
           
        15). Remote and local control circuit connection
           
        16). Button switched double speed motor speed control circuit connection
           
        17). Time relay switched double speed motor speed control circuit connection
           
        18). Centrifugal switch coupled reverse braking control circuit connection            
        • Frequency converter panel function parameter setting and operation training            
        • Motor inching control, start and stop control of frequency converter
           
        • Motor speed multistratum control
           
        • Power frequency, variable frequency switching control            
        • Analog quantity control based motor open loop speed regulation            
        • Panel operation based motor open loop speed regulation
           
        • Frequency converter protection and warning function training
           
        • PLC based frequency converter open loop speed regulation            
        • PLC controlled motor sequential starting
           
        • PLC controlled three-phase asynchronous motor Y-∆ starting circuit            
        • Touch screen, PLC, frequency converter comprehensive training
           
        • Two phase hybrid stepping motor control
           
        • AC servo motor control            
        TECHNICAL PARAMETERS            
        1. Input Voltage : Three-phase five-wire, AC 380V/220V ±7.5%, 50Hz            
        2. Working environment: Insulated floor or carpet
           
        3.Training device main meshed plate size: 798mm×768mm            
        4.Training device dimensions: 2006mm×1003mm×2410mm            
        5.Training device material: steel plate, thickness≥1.5mm            
        6. Maximum power consumption: ≤1.5KW            
        >BASIC CONFIGURATION            
        • Distribution Box            
        (1) 3-phase-4-wire active energy meter (1pcs)            
        (2) Fuse type isolator (3-pole, 32A) (1pcs)            
        (3) RCCB (3P+N) (1pcs)
           
        (4) Air switch(3P) (1pcs)            
        (5) 3-phase-4-wire leakage switch (1pcs)
           
        (6) Button label frame (3pcs)
           
        (7) Steel DIN rail (210mm) (1pcs)
           
        (8) Indicator (red, green, yellow) (3pcs)
           
        (9) Distribution box body (450mm×230mm×520mm) (1pcs)            
        (10) Mounting screw (M4*12) (11pcs) (11) Earth terminal (1pcs)            
        • Electrical Control Box            
        (1) Combination switch (3-pole) (1pcs)
           
        (2) MCCB breaker (20A, 3-pole) (1pcs)
           
        (3) Contactor(220V) (7pcs)
           
        (4) Auxiliary contact (5pcs)
           
        (5) PLC (Mitsubishi 48 I/O) (1pcs)
           
        (6) Analog quantity module (1pcs)
           
        (7) Frequency converter(0.75KW) (1pcs)
           
        (8) Time relay (AC220V, 2 off-delay) (1pcs)
           
        (9) Time relay (1 instantaneous, 1 delay) (1pcs)            
        (10) Thermorelay (3pcs)
           
        (11) Temperature controller (1pcs)
           
        (12) Terminal block (4pcs)
           
        (13) Switching power supply (2pcs)
           
        (14) HMI (Mitsubishi) with communication cables (1pcs)            
        (15) Mounting rail (240/500/150mm) (3pcs)
           
        (16) Mounting screw (M3*10) (34pcs)
           
        (17) Mounting screw (M4*15) (12pcs)
           
        (18) Mounting screw (M3*15) (4pcs)
           
        (19) Mounting screw (M6*25) (5pcs)
           
        (20) Control box body (500mm×230mm×700mm) (1pcs)            
        (21) Button (5red, 5green) (10pcs)
           
        (22) Emergency stop switch (1pcs)            
        (23) Indicator (220V, 5 red, 5 green) (10pcs)            
        (24) Selective switch(2 grade) (2pcs)
           
        (25) Selective switch(3 grade) (2pcs)
           
        (26) Data line (RS232C/RS422) (1pcs)            
        (27) Rocker switch (1pcs)
           
        (28) Protective ring (¢4) (3pcs)            
        (29) Heater cable (2pcs)            
        • Motor Unit            
        (1) Three-phase AC asynchronous double speed motor (1pcs) (2) Three-phase AC asynchronous motor (1pcs)            
        (with centrifugal switch) (180W, Y-∆, 1400r/min, 0.4A, 380V) (3) Three-phase AC asynchronous motor (1pcs)            
        (180W, Y-∆, 1400r/min, 0.4A, 380V)
(4) Wall mounted motor support (2pcs)
(5) Motor mounting base with carrying handles (1pcs)            
        • Motion Control Unit            
        (1) Ball screw (500mm) (1pcs)
(2) Stepping motor (1.8o/0.5Nm, 1.7A) (1pcs) (3) Stepping motor driver (4-in/6-out) (1pcs)            
        .    (4)  Terminal block (1pcs) 
           
        .    (5)  Servo connector with metal guide rail (1pcs) 
           
        .    (6)  Travel switch (2pcs) 
           
        .    (7)  Optoelectronic switch (NPN, NO, 20cm) (1pcs) 
           
        .    (8)  Capacitive sensor (NPN, NO, 1-10mm) (1pcs) 
           
        .    (9)  Proximity switch (1pcs) 
           
        .    (10)  Servo driver (400W) (1pcs) 
           
        .    (11)  Servo motor (input AC110V, output 300r/min) (1pcs) 
           
        .    (12)  Switching power supply (1pcs) 
           
        .    (13)  Mounting base (820mm×370mm) 
           
        .    (9)  Switch(2) (2pcs) 
           
        .    (10)  Switch(4) (2pcs) 
           
        .    (11)  Ceiling lamp (1pcs) 
           
        .    (12)  Touch switch (1pcs) 
           
        .    (13)  Concealed bottom box (6pcs) 
           
        .    (14)  Junction box panel (2pcs) 
           
        .    (15)  External box (86) (4pcs) 
           
        .    (16)  External box (3pcs) 
           
        • Sensor Unit            
        (1) Travel switch (4pcs)
           
        (2) Capacitance type sensor
           
        (3) Inductance type transducer (1pcs)
           
        (4) Photoelectric transducer (1pcs)
           
        (5) Temperature sensor (Pt100) (1pcs)
           
        (6) K type thermal resistance/thermocouple) (1pcs)            
        (7) Protective ring (¢10) (4pcs)
           
        (8) Terminal block (1.5*15) (1pcs)
           
        (9) Terminal block (1.5*5) (2pcs)            
        (10) Connecting lead (2.8m) (11) Screw (M4*15) (8pcs)            
        • Lighting Kit            
        (1) Integrated fluorescent tube (10W) (1pcs)            
        (2) Energy saving lamp (9W~13W) (2pcs)            
        (3) Sodium lamp (ballast:110W) (1pcs)
           
        (4) Flat screw cap (2pcs)            
        (5) Voice operated switch (86) (1pcs)            
        (6) Socket(1-plug) (2pcs)
           
        (7) Socket(2-plug) (1pcs)
           
        (8) Switch(1) (1pcs)            
        (1pcs)            
        • Line Material            
        (1) PVC line pipe (Φ16,3m) (2pcs)
           
        (2) PVC direct connection (Φ16) (10pcs)            
        (3) Lock catch (Φ16) (30pcs)
           
        (4) Ribbon (3*100mm) (500pcs)
           
        (5) Screw (M4*20, with nut) (200pcs)
           
        (6) PVC trunking (2m) (20×10mm) (3pcs)            
        (7) PVC trunking (30×17mm) (3pcs)
           
        (8) Insulated wire (1.5mm2) (3pcs)
           
        (9) Insulated wire (1.0mm2) (2pcs)            
        (10) Pipe clamp (Φ16) (30pcs)
           
        (11) Metal cable bridge (500mm) (6pcs)
           
        (12) Metal cable bridge (200mm) (3pcs)
           
        (13) 90°elbow (50*25) (100×100×25mm) (1pcs)            
        (14) Vertical turning elbow joint (2pcs)
           
        (15) Bridge head with hole (bore 23) (1pcs)
           
        (16) Connecting plate (50*25, 45° elbow) (2pcs)            
        (17) Horizontal straight T-joint (2pcs)
           
        (18) Vertical T-joint (1pcs)
           
        19() Horizontal cross joint (1pcs)
           
        (20) Vertical upper elbow joint (1pcs)
           
        (21) Vertical lower elbow joint (1pcs)
           
        (22) Trunking support (12pcs)
           
        (23) Connecting plate (18pcs)
           
        (24) Connecting screw suite (nut, flat/spring gasket)            
        (25) Cable with marker(1.5mm) (6m)
           
        (26) Cold pressed terminal (Φ1.5) (300pcs)
           
        (27) Take-up strap (Φ10, 10m) (2pcs)            
        • Training Bench            
        (2006mm×1003mm×2410mm)            
        (1) Stand column (4pcs)
           
        (2) Large meshed plate (10pcs)
           
        (3) Small meshed plate (4pcs)            
        (80pcs)            
        • Electrician Tools            
        (1) Sharp-nose pliers (125mm) (1pcs)            
        (2) Wire stripping pliers (1pcs)
           
        (3) Crimping pliers (1pcs)
           
        (4) Wire nippers (200mm) (1pcs)            
        (5) Straight screwdriver(Φ4×100mm) (1pcs)            
        (6) Cross screwdriver (Φ4×100mm) (1pcs)            
        (7) Electroprobe screwdriver (500V) (1pcs)            
        (8) Multimeter(MF500) (1pcs)            
        (9) Aluminum alloy herringbone ladder (1.5m) (1pcs)            
        (10) Flat file(200mm) (1pcs)
           
        (11) Steel tap(3m) (1pcs)
           
        (12) Electrician's knife (105mm) (1pcs)            
        (13) Steel square(300mm) (1pcs)
           
        (14) Straight steel ruler(200mm) (1pcs)            
        (15) Monkey wrench (6") (1pcs)
           
        (16) Hex wrench kit (9-piece) (1pcs)
           
        (17) Fuse (15A) suite (1pcs)
           
        (18) Hand saw (1pcs)
           
        (19) Hand saw blade box (1pcs)
           
        (20) PVC pipe bender (Φ16) (1pcs)
           
        (21) Tramegger (500V) (6pcs)
           
        (22) Angular grinder (Φ70) (1pcs)
           
        (23) Abrasive wheel cutting machine (1pcs)            
        (200mm with shield)
           
        (24) Electric hand drill (1pcs)
           
        (25) Power plugboard (4-plug) (2pcs)            
        • Movable tool station: 930mm×740mm×860mm,            
        with heavy loading and self-locking trundle            
        • Electrical heater (1pcs)            
        (4) Three layer frame (4pcs)
           
        (5) Single layer frame (2pcs)
           
        (6) Long meshed junction plate
           
        (7) Short meshed junction plate (1pcs)            
        (8) Back beam (1pcs)            
        (9) Front beam (1pcs)
           
        (10) Meshed beam column (3pcs)
           
        (11) Side beam (2pcs)
           
        (12) Self-locking truckle (¢75) (4pcs)
           
        (13) Short mounting screws (hexagonal,M6*40mm) (100pcs)            
        (14) Mounting screws (hexagonal,M6*60mm) (35pcs)
           
        (15) Long mounting screws (hexagonal,M6*150mm) (65pcs)            
        (16) Flat washer (¢6) (400pcs)
           
        (17) Spring washer(¢6) (200pcs)
           
        (18) M6 nut (200pcs)            
2    Basic Electric Training System    Features :           
        • This trainer is designed for the training of electric traction control and lighting circuit, it adopts double sided cabinet structure to save the operation space and ensure operation for two training groups at the same time.            
        • The wiring base board is mounted with various electrical control related low-voltage apparatus, including fuse protectors, contactors, intermediate relays, time relays, thermorelay, travel switches, buttons, signal lights, change-over switch, voltmeter, ammeter, etc. All contact points of electric appliances are connected with terminal blocks for efficient wiring and long term service life.            
        • Safety protection system: Before each experimental module is powered, the three phase power source from electrified wire netting passes through leakage protector, current /voltage protector and breaker. Leakage protection device and overcurrent protection device are adopted to cut off the main power automatically when leakage, short circuit or overload happens.            
        > TRAINING CONTENT            
        Electric Traction Circuit            
        • Three phase asynchronous motor direct starting control
           
        • Three phase asynchronous motor contactor jog control
           
        • Three phase asynchronous motor contactor self-locking control            
        • Manual reduced voltage starting control of three phase asynchronous motor stator series resistance
           
        • Automatic reduced voltage starting control of three phase asynchronous motor stator series resistance            
        • Automatic Y/∆ starting control
           
        • Contactor interlocked three phase asynchronous motor forward and reverse control
• Button interlocked three phase asynchronous motor contactor forward and reverse control
           
        • Double-interlocked three phase asynchronous motor forward and reverse control
• Three phase asynchronous motor unidirectional reduced voltage starting and reverse braking control            
        • Three phase asynchronous motor dynamic braking control
           
        • Three phase asynchronous motor sequential control
           
        • Three phase asynchronous motor remote and local control            
        • Jog starting control of three phase asynchronous motor forward and reverse            
        • Work table automatic round trip control
           
        • Work table automatic jog round trip control
           
        • X62W type universal milling machine spindle and feed motor gang control            
        • C620 lathe control circuit
           
        • Electric block electrical control circuit            
        • Unidirectional motor starting control            
        Lighting Circuit            
        • Incandescent light control circuit
           
        • Fluorescent lamp control circuit
           
        • Touch switch controlled incandescent light control circuit
           
        • Voice operated switch controlled incandescent light control circuit
           
        • Single phase kilowatt hour meter installation circuit
           
        • Installation of three phase-four-wire active kilowatt hour meter
           
        • Installation of three phase-four-wire reactive kilowatt hour meter
           
        • Voltmeter and ammeter installation circuit
           
        • Wiring circuit of using universal change-over switch and voltmeter to measure three phase line voltage            
        • One current transformer used single loop wiring circuit
           
        • Two current transformers connected incomplete star connection circuit
           
        • Three current transformers connected star connection circuit
           
        • Two current transformers differential connected wiring circuit
           
        • Three current transformers connected delta connection circuit            
        >TECHNICAL PARAMETERS            
        1. Input voltage: three phase 380V(or 220V) ±10%, 50Hz, 20A
           
        2. Working environment: Ambient temperature range: -5°C~+40°C, Relative humidity < 85% (25°C), Altitude< 4000m            
        3. Dimensions: 800mm×520mm×1790mm
           
        4. Packing weight: 150kgs            
        >BASIC CONFIGURATION            
        Main training cabinet: It adopts iron matte microgroove power coated structure, coming with two doors and heat emission holes on front /back side, each door is equipped with a sheltered and lockable hand.            
        The electric side
is designed with pointer type voltmeter 0~450V (or 0~250V), ammeter 0~5A (3pcs), rotary switch (2pcs), control button (6pcs), indicating lamp (8pcs) and universal change-over switch.            
        Two iron plates are used for the mounting of electrical components and parts on each side. 
           
        Power supply control panel:
           
        (1). Control transformer: input 220V/380V, output 6.3V/24V/36V/110V.
           
        (2). Providing single phase 220V and three phase 380V(or 220V) AC power supplies. The AC power supply 
is set with current, voltage protection, automatic inter-phase/wire overcurrent and overvoltage protection.            
        (3). High voltage DC power supply: 220V(1A) DC power supply
           
        (4). Safety protection system: Before each experimental module is powered, the three phase power source 
from electrified wire netting passes through leakage protector, current /voltage protector and breaker. Equipped with leakage protection device and overcurrent protection device, it can cut off the main power automatically when leakage, short circuit or overload happens. 
           
        3. AC contactor: Provided with four AC contactors (110V, 4NO) and four auxiliary contacts (2NC/2NO).            
        4. Thermorelay: Provided with two thermorelays and five fuse protectors.
           
        5. Intermediate relay module: Provided with two intermediate relays.
           
        6. Travel switch module: Provided with six travel switches.            
        7. Electrical control module: Provided with a rectifier bridges and three adjustable resistors.            
        8. Time relay: Provided with two power on delay type time relays (0~10s).
           
        9. Common type miniature relay: Provided with two miniature relays (2NC/2NO).            
        10. Basic skill training module: Provided with single-phase kilowatt hour meter and three current transformers (through-core turns: 1, rated capacity: 5/3.75VA), it can be combined with power supply control panel to achieve basic skills training, such as single-phase kilowatt hour meter installation circuit training, three-phase watt-hour meter installation circuit training, current transformer circuit training, universal change-over switch and voltmeter measuring three phase voltage training.            
        11. Fluorescent lamp module: Provided with 20W fluorescent lamp suite (starter, ballast) and a single-pole double-throw switch, it can be used to finish skills training such as fluorescent lamp training, remote and local controlled one lamp circuit and common instrument installation circuit experiment.            
        12. Three-phase watt-hour meter(2pcs)
           
        13. Incandescent light(6pcs), voice/touch/double control switches and socket
           
        14. Three phase squirrel cage asynchronous motor: two three phase squirrel cage asynchronous motors.            
        15. Single phase capacitance type motor: slow terminal            
        medium terminal fast terminal            
        15. Connecting leads:
           
        (1) two-end banana plug wire            
        (2) U type cold-pressed terminal            
        and banana plug wire            
3    Electricity Protection Training System    I. Product overview           
        It can through training, let students be familiar with various electric accident reasons so as to prevent electric           
        accident occur. Through learning, students will learn of how the accident occurs, and take cautions on electric           
        accident, so as to enhance the ability of prevent accident, solve electric accidents. Students can learn many safety           
        protection mode in the trainer.           
        2 Feature           
        Training workbench use aluminum column, testing measures, inner integrated training power box. It is easy           
        to use, and it is not easy to be broken.           
        Modular structure: it has many modules, and it can achieve many training projects, please see theexperiment list later.           
        It has good safety protection system, all the electric terminals select safety plug terminals, the whole set can           
        be connected to ground, if there is electric leakage occurs, students can ct off power immediately, so as to protect themselves.           
        3. Technical parameter           
        Input power: single phase three wire, 220V±10% 50Hz           
        Dimension: 1600mm×800mm×1800mm           
        Whole capacity:<2.0KVA           
        Weight: <100kg           
        Work condition:           
        Environment temperature:-10℃~+40℃           
        Relative humidity: <85%(25℃)           
4    Low and Middle Voltage Simuation Training System    Features :           
        • This trainer is a comprehensive electrician operation platform that covers topics such as the electrician tools, electrician instruments, electrician security, electrician operation, etc. It is developed to meet the training requirements for electrical appliance installation, wiring technology, circuit analysis, mechanical electrical control circuit experiment, fault analysis and so on.            
        • The frame structure is made of 1.2mm thickness aluminum alloy, coming with circular arc transition interface and trapezoid design. The metal surface is acid cleaned, phosphate treated and epoxy resin powder coated, which is heat/erosion resisting.            
        • The table top adopts high density fire-proof plate and the table bottom is equipped with movable and lockable truckles for easy movement.            
        • Antifouling and antifading aluminum plastic board is adopted as the mounting plate of hanging modules, each module comes with two handles for convenient operation            
        • Two groups of power supply units are provided to achieve training for two students at the same time. The power supply, instrument and meter used in this trainer is reliably protected, with personal security protection system.            
        > TRAINING CONTENT            
        • Continuous running of motor in single direction (with jog control)
           
        • Three phase asynchronous motor forward and reverse
           
        • Single phase watt hour meter with lighting control
           
        • Motor running control circuit (with fuse, breaker, meters, current transformer)            
        >TECHNICAL PARAMETERS            
        Dimension: table 1600mm×700mm×750mm (approx.), bench 1580mm×230mm×950mm (approx.) 
           
        Input voltage: Three phase 380V±10%, 50Hz 
           
        Working environment: temperature -10°C~+40°C, RH˂85%(25%), height˂4000m 
           
        Installed capacity: ˂3kVA 
           
        Personal safety protection: Current mode leakage protection, voltage mode leakage protection, (protection current I∆n≤30mA, break-time≤ 0.1s) overvoltage, overcurrent and overload protection. 
           
        >BASIC CONFIGURATION            
        Training table: aluminum alloy frame with high density plate tabletop, two drawers and cabinets for the storage of accessories, four universal truckles with braking mechanism.
           
        Training bench: provided with upper hanging boards frame and lower fixed power supply/measurement panel. The framework is made of aluminum alloy, with circular arc transition interface. 
           
        Three phase asynchronous motor: 1PCS, 180W, star/triangle connection with aluminum alloy shell. 
           
         Independent control power unit (2 groups): 
           
        (1) Main power switch unit: with leakage protector, fuse units for U, V, W phase.
           
         (2) AC three phase four-line 380V/220V output unit: provided with AC 450V voltmeter, U/V/W indicators, U/V/W/N/PE 
safety output voltage sockets.
           
        (3) Low voltage AC power output unit: provided with 0V/3V/6V/9V/12V/18V/24V/36V multi-tap AC power outputs.            
         (4) DC stabilized power supply unit:0~30V continuously adjustable, current 1.5A, voltage/current stability˂0.3%, 
automatic relay shifting, automatic overload protection, automatic recovery and overload indication functions. provided with 30V voltmeter, voltage coarse and fine adjustment rotary knobs, positive and negative connecting sockets, etc. 
           
        (5) AC voltmeter, ammeter unit: AC voltmeter range 0~450VAC, AC ammeter range 0~3A. 
(6) AC 220V power output(2pcs): multifunctional sockets, providing power for external equipment. 
           
        Electricity safety unit: 
           
        (1) Key switch electricity achieving unit: each trainer is equipped with this unit to make sure the power supply can only be started by particular key, so as to avoid damage caused by reckless operation. 
           
        (2) Emergency stop switch unit: by using this switch to cut off power supply rapidly, so as to prevent deterioration. 
           
        >FUNCTIONAL DISTRIBUTION MODULE            
        1. Motor single direction continuous running control            
        (1) 3P air switch (1pcs)
           
        (2) Fuse protector (3pcs)
           
        (3) AC contactor (1pcs)            
        (4) Three-hole button box (1pcs)            
        (5) Red button (1pcs)
           
        (6) Green button (1pcs)
           
        (7) Yellow button (1pcs)            
        (8) Safety sockets            
        (9) Carrying handle            
        2. Three phase asynchronous motor forward and reverse control            
        (1) 3P breaker (1pcs)
           
        (2) Fuse protector (3pcs)
           
        (3) AC contactor (2pcs)            
        (4) Three-hole button box (1pcs)            
        (5) Red button (1pcs)
           
        (6) Green button (1pcs)
           
        (7) Yellow button (1pcs)            
        (8) Safety sockets            
        (9) Carrying handle            
        3. Single phase watt hour meter with lighting control            
        (1) 2P breaker (1pcs)
           
        (2) Fuse protector (2pcs)
           
        (3) Single phase watt hour meter (1pcs)            
        (4) E27 screw bulb (2pcs)
           
        (5) 86 double controlled switch (1pcs)            
        (6) Five-hole 86 socket (1pcs)
           
        (7) Safety sockets
           
        (8) Carrying handle            
        >Motor and leads            
        4. Motor running control circuit            
        (1) 3P breaker (1pcs)
           
        (2) Fuse protector (3pcs)            
        (3) AC contactor (1pcs)            
        (4) Three-hole button box (1pcs)            
        (5) Red button (1pcs)
           
        (6) Green button (1pcs)
           
        (7) Yellow button (1pcs)            
        (8) Voltmeter AC450V (1pcs)            
        (9) Ammeter AC0~3A (1pcs)            
        (10) Current transformer (1pcs)            
        (11) Safety sockets
           
        (12) Carrying handle            
        1. Three phase AC 380V motor, star/delta convertible
           
        2. Connecting leads: CKC safety type, color red/green/yellow/blue/black 30pcs each.            
5    Frequency Control Speed Regulation Experiment System    Features :           
        • This trainer adopts high performance and multi-functional Mitsubishi FR-A740-1.5K (380V, 1.5KW) as the mainframe, which has FR-A74P option inside and is equipped with pulse encoder motor braking and speed measuring system.            
        • Open loop/closed loop system experiment and frequency converter functional experiment can be accomplished
by operating this trainer, moreover, with open type structure, students can learn and master the structure principle, detection and maintenance skill of frequency converter as well.            
        > EXPERIMENTS            
        • PU inching running experiment
           
        • External inching running experiment            
        • Open loop running experiment
           
        • External operation experiment
           
        • Combined operation experiment
           
        • Procedure running experiment
           
        • Multistage speed running experiment            
        >TECHNICAL PARAMETERS            
        1. Input power supply: AC 380V ±5%, 50Hz            
        2. Rated current: 3A
           
        3. Environment temperature: -10°C~+40°C            
        4. Dimension :1600mm×730mm×1500mm            
        5. Relative humidity: ≤90% (25°C)            
        6. Frequency converter: Mitsubishi FR-A740-1.5K            
        >PRODUCT COMPOSITION            
        • Speed feedback system experiment
           
        • Interrupt power-supply starting experiment
           
        • Speed positioning system experiment
           
        • PID control system
           
        • Network control experiment
           
        • Communication operated running experiment            
        1. Experimental platform: Installed with all electrical apparatus elements, instruments, switches, buttons and so on.            
        2. Load motor: Three phase asynchronous motor
           
        3. Motor guide rail and optical encoder pair
           
        4. Training table            
6    Programmable Logic Controller Training Set    Features :           
        • This trainer is suitable for courses such as 'PLC Technology', , 'Electric Appliance and PLC Control Technology' and 'PLC Application'.            
        • It is mainly composed of control panel, PLC mainframe, modular simulation modules and so on.            
        • The training table adopts plastic sprayed steel structure and designed with drawer, which is convenient for the storage of tools and modules. The table top is made up of high density board, with fireproof, waterproof and wearproof function.            
        • Frequency converter and motor can be added to extend the experiment content when needed. (optional)            
        • Safety protections: grounded, lead protection, safety in accordance with related GB standards. Insulated safety sockets, sheathed cables and wires.           
        TRAINING CONTENT            
        • PLC basic instruction training            
        • Motor forward and reverse control simulation            
        • Television transmitting tower simulation            
        • Traffic light control system simulation            
        • Automatic goods delivery and loading system simulation            
        • Automatic water tower water level control simulation            
        • Automatic molding machine system simulation            
        • Various liquids automatic control system simulation            
        • Automatic punching machine control system simulation            
        • Elevator control system simulation            
        • Automatic mail sorting system simulation            
        • Automatic washing machine control system simulation            
        • Plating control system simulation            
        • Automatic vending machine system simulation            
        • Relay control experiment            
        • Software simulation control           
        TECHNICAL PARAMETER            
        1. Input Voltage : AC 380V/220v, 50Hz 2. Temperature : -5~40°C, Below RH 90% 3. Overall power consumption: 0.3 kVA 4. Dimensions: table 1575mm×680mm×835mm (approx.) bench 1130mm×250mm×720mm (approx.) >BASIC CONFIGURATION 1. Training table: it adopts steel-wood material, with 16mm medium density fiberboard as the tabletop. The frame is made of rectangular steel tubes. The structure is designed with two drawers, PC cabinet, keyboard tray and lockable universal wheels.            
        2. Round stool (2pcs): Screw lifting range: 450~500mm, seat size: 300mm×300mm (approx.)            
        3. Control panel:            
        (1) AC power control unit: It is equipped with lighted fuse and leakage protection switch and provided with three phase 380V and single phase 220V power supply (one group each), which can be controlled by start-stop switches. Three-phase-four-wire AC 380V supply via air switch and can be monitored by voltmeter.            
        (2) Timer and alarm recorder: It has time setting, timing alarm, power cut-off function and can automatically record the electric leakage alarm time, which is caused by connection or operation.            
        (3) DC stabilized voltage: 0~30V adjustable, with rough/accurate adjust rotary knobs.            
        (4) DC constant current source: 0~200mA adjustable, with rough/accurate adjust rotary knobs.            
        (5) DC digital voltmeter: 0~200V, 10MΩ, class 0.5            
        (6) DC digital ammeter: 0~200mA, class 0.5            
        (7) Logic level output and indicator, self-locking/jog buttons            
        (8) Programmable logic controller: FX1N-40MR, 24I/16O, relay output            
        4. PLC simulation module (standard modular dimension 150mm×288mm×50mm)            
        (1) Motor positive and negative rotation control            
        (2) Television transmitting tower            
        (3) Traffic light control system            
        (4) Automatic goods delivery and loading system            
        (5) Automatic water tower water level control            
        (6) Automatic molding machine system            
        (7) Various liquids automatic control system            
        (8) Automatic punching machine control system            
        (9) Elevator control system            
        (10) Automatic mail sorting system            
        (11) Automatic washing machine control system            
        (12) Plating control system            
        (13) Automatic vending machine system            
        (14) Relay control experiment            
        5. Experiment wire: Length: 40cm/60cm/100cm, red/yellow/black, 60pcs in total.            
        6. PLC Programming software(copy): GX-Developer, It can accomplish the edit of PLC ladder diagram, instruction list, SFC,etc. The program can be saved as GPPQ, GPPA format.            
        7. Programmable cable: USB2.0 PC port, round head 8-pin PLC port, with 3 color LED communication indicator and driver disc (one-button type installation, available for windows XP, VISTA, WIN7, etc.).            
        8. Simulation software (copy): GX simulator.            
        9. PLC program: Programs for 14 simulation modules, 27 basic instructions, advanced instruction application            
        10. Power socket           
7    Servo Motor Trainer    Features :           
        DC MOTOR CLOSED-LOOP CONTROL (POSITION) EXPERIMENTAL PORTABLE CASE           
        XK-DCSF2 is one kind of experiment device that help user learn the DC motor position closed-loop regulating loop (P.I.D). XK-DCSF2 consists of perturbance circuit, P circuit, I circuit, D circuit, added circuit and motor drive circuit. XK-DCSF2 box adopts aluminium alloy structure, composed by high performance DC motor components.           
        Overall size: 450×300×150 mm, Weight: 4.5Kg           
        Power source: single phase, AC220V, frequency: 50/60Hz, power ≤15VA           
        With power supply indication, main power indication, grounding protection and           
        Over current protection           
        Working environment: temperature -10℃~+40℃           
        TRAINING ITEMS           
        The understanding of the DC motor           
        The understanding and application of the DC motor drive           
        DC motor manual control experiment           
        P (position) closed-loop control experiment           
        PI (position) closed-loop control experiment           
        PID (position) closed-loop control experiment           
        DC motor typical position loop control (PID) experiment           
        DC motor disturbance signal closed-loop position control (PID) experiment           
8    Step Motor Training Set    1,Product Overview:           
        Stepper motor test box by DC12V four-phase stepper motor, PIC microcontroller control unit PLC control interface unit, the control button, indicator, and other components. Suitable for students at PLC, microcontroller programming control training, and stepper motor control training. Communication with the PC through the USB port.           
        2,Main parameters:           
        1, Supply voltage: AC220V, 50Hz;           
        2, Current: ≤ 1A;           
        3, Size: 370mm * 220mm * 120mm (L * W * H);           
        4, Weight: 5KG;           
        5, The stepper motor.           
        3,Main function:           
        1, learning the work of the four-phase stepper motor and control methods.           
        2, learn how to use microcontroller to control the four-phase stepper motor.           
        3, learn how to use the PLC to control the four-phase stepper motor.           
        4, learning to use the PC + single-chip control of the four-phase stepper motor.           
9    Electrical Installation Training System     Features :           
        • This trainer is composed of training table and meshed plate. The electrical control circuit components can be mounted on the meshed plate for training, which is easy to operate and convenient for function extension.            
        • By selecting related components according to training requirements student can conduct components arrangement and installation on the meshed plate and finish the wiring themselves. which is good for operational ability development.            
        • Voltage mode leakage protector and current mode leakage protector are adopted to ensure safety. Each power output is designed with monitoring and short circuit protection functions. The measuring instruments are also designed with reliable protection function.            
        • It is suitable for two students to experiment at the same time, with independent power unit and structure.            
        > EXPERIMENTS            
        • Three phase asynchronous motor inching control circuit
           
        • Three phase asynchronous motor contactor self-locking control circuit
           
        • Three phase asynchronous motor single direction inching starting control circuit
           
        • Three phase asynchronous motor remote and local control circuit
           
        • Forward and reverse inching/starting control circuit
           
        • Double-interlocked forward and reverse control circuit
           
        • Automatic round trip control circuit
           
        • Forward and reverse starting control circuit (position switch used for automatic stop)            
        • Automatic round trip control circuit with inching
           
        • Three phase asynchronous motor Y/∆ control circuit
           
        • Contactor controlled Y/∆ control circuit
           
        • Series resistor reduced voltage starting control circuit
           
        • Three phase asynchronous motor reverse barking control circuit
           
        • Three phase asynchronous motor energy consumption braking control circuit
           
        • Manual sequential starting control            
        • Automatic sequential starting control
           
        • C620-1 lathe control circuit
           
        • Electric block electrical control circuit
           
        • Human inductive switch controlled stair incandescent light circuit            
        • Voice operated switch controlled stair incandescent light circuit            
        • Fluorescent lamp control circuit
           
        • Single phase watt-hour meter direct mounting circuit
           
        • Single phase watt-hour meter indirect mounting circuit
           
        • Current transformer and ammeter matched wiring diagram
           
        • Voltmeter and ammeter mounting circuit
           
        • Three phase four-wire active watt-hour meter direct mounting circuit
           
        • Three phase four-wire active watt-hour meter indirect mounting circuit            
        • Wiring circuit of one current transformer used for single phase loop
           
        • Two current transformers star connected incomplete wiring circuit
           
        • Three current transformers star connected wiring circuit
           
        • Two current transformers differentially connected wiring circuit
           
        • Three current transformers delta connected wiring circuit            
        >TECHNICAL PARAMETERS            
        1. Input voltage: three phase 380V ±10%, 50Hz
           
        2. Working environment: Temperature: -10°C~+40°C, Relative humidity < 85% (25°C), Altitude< 4000m            
        3. Dimensions: 1600mm×750mm×1800mm
           
        4. Installed capacity: < 3 kVA            
        >BASIC CONFIGURATION            
        AC instrument:
           
        (1) AC voltmeter (2pcs): Measuring range 0~500V, precision class 1.0
           
        (2) AC ammeter (2pcs): Measuring range 0~5A, precision class 1.0, with outrange alarm, indication and power 
cut off functions. 
           
        Power supply: Provided with 380V line voltage and 220V phase voltage, the power supply part adopts aluminum 
alloy frame (2cm), with dimension of 1520 mm×180mm×200mm.
           
        (1) Excitation source: 220V, 0.5A
           
        (2) Adjustable DC power supply: 0~220V, 3A, with DC instrument for indication, precision class 1.0 
           
        Meshed plate: Each station is provided with one stainless steel meshed plate (600mm×730mm), which can be mounted on the control panel between two square tubes. The meshed plate can be replaced easily, it
is ideal for component installation and arrangement. 
           
        Training table: It adopts 40mm×80mm aluminum alloy as the main frame, the key parts of it is strengthened
by triangular unit with socket head cap screws, the surface of it is powder coated, which is antirust and insulated. The table top is made of 25mm thickness waterproof, fireproof and wearproof high density board. Standard drawer type cabinet (1110 mm×630mm×510mm) is adopted for the storage of tools and training data, the left part of it is a three-layer drawer and the right part of it is designed with two doors. There are four universal wheels on the bottom of table for easy movement. 
           
        5 Training tool kit: Provided with digital multimeter, wire stripper, nipper pliers, diagonal pliers, cross screwdriver, straight screwdriver, electric soldering iron, electroprobe, electrician's knife, etc.            
        6. Training stool: PP injection moulded surface plate, ABS injection moulded sheathing, screw lifting structure with circular tube of 50 mm diameter and 1.2mm thickness.            
        7. Accessories: Training guidebook, tool kit, wiring materials, etc.            
        8. Components list:            
        (1) Low-voltage circuit breaker (1pcs)            
        (2) Screw type fuse (3A) (3pcs)
           
        (3) Straight plug type fuse (2A) (2pcs)            
        (4) AC contactor (3pcs)            
        (5) Auxiliary contact (2pcs)
           
        (6) Thermorelay (1pcs)
           
        (7) On-delay time relay (380V with seat)            
        (8) Terminal block (5pcs)
           
        (9) G terminal guide rail (1pcs)            
        (1pcs)            
        (10) Control transformer (50W) (1pcs)
           
        (11) Button switch box (three switches) (1pcs)
           
        (12) Button switch box (two switches) (1pcs)
           
        (13) Button (without lamp) (5pcs)
           
        (14) Travel switch (3pcs)
           
        (15) Resistor (510Ω, 50W) (3pcs)
           
        (16) Three phase four-wire active watt-hour meter (1pcs)
           
        (17) Single phase watt-hour meter (1pcs)
           
        (18) Current transformer (30/5A) (3pcs)
           
        (19) Voice operated switch (#86) (1pcs)
           
        (20) Time delay touch switch (#86) (1pcs)
           
        (21) Incandescent lamp (36V) (1pcs)
           
        (22) Fluorescent lamp (with ballast, starter, 18W) (1pcs)
           
        (23) Reversible switch (1pcs)
           
        (23) Screws (90pcs)
           
        (22) Three phase squirrel cage asynchronous motor (380V/∆) (2pcs)            
        (23) Plastic mounting clamp (190pcs)            
                   
                   
                   
10    Multi Function Measuring Instrument System    Features           
        Convenient module changes with one-touch connection way           
        Supply all input power by a main component           
        DC,Ac Power signal about input signal is available with an additional function generator           
        Comparison experiment is available about changing of characteristics and variables           
        Easy Access about circuit with graphic expression of module circuits           
        Digital multimeter,function generator are included in the main equipment also           
        Waveform of function generator is consist of sinewave,triangle wave,square wave,sawtooth wave           
        Resource control using a 10.1" tablet PC and oscilloscope drive (option)           
        Technical Data           
        Power supply    DC output : +/- 0~20V 2A, ±5V 1A,±15V 1A       
            AC output 240V 0.5A, 12V 0.5A       
        Digital Multimeter    AC/DC Voltage : 1mV~400V       
            DC Current 1mA~4A       
            Resistance 0~4 MΩ       
        Function Generator    1Hz ~ 100Khz (Max 20Vp-p)       
            sinewave,trianglewave,squarewave,sawtoothwave       
        Realtime control    OS : windows 10/ Android Lollipop 5.1.1       
        Laboratory    CPU : Intel Atom Bay Trail-TZ3735F/Quadcore/1.33Ghz       
            RAM : DDR 2GB       
            In memory 32GB       
            Out Memory Maximum 128GB support       
            LCD : 10" IPS Screen       
            Resolution 1280x800       
            Touch pannel : 10 point capacitive multi-touch screen       
            Size 257x172x10mm       
        Input Power    Bandwith 25MHz       
        Inner Oscilloscope    Channels 2       
        (Option)    Vertical Resolution 8 bits       
            Bandwitdth 25MHz       
            Input ranges +50mV~+20V       
            Overvoltage protection +100V       
            Memory 16Kb       
            Maximum sample rate 200ms       
            Trigger modes : none,auto,repeat,single       
            Automatic measurements : scope mode,statistics       
            Spectrum mode : frequency at peak,amplitude at peak THD db,SNR-SINAD,SFDR       
            totalpower,average amplitude at peak       
            Mask limit testing : mask generation (numeric or graphical)       
            SDK/API :       
            32 and 64 bit drives for windows 7,8 and 10       
            Linux drivers, mac OS X drivers       
        Including training module :           
        Electric & Electronic :           
        DC Circuir,Measuerement Circuit,AC Circuit,Transformer,Semiconductor,Transistor Amplier           
        OP Amplifier,Active Filter ,Power Supply, Oscillator,Pulse Circuit,Digital Logic,Sequential Logic           
        Combination logic etc.                    

Alat SMK 2018 ,KOMPETENSI KEAHLIAN TEKNIK INSTALASI TENAGA LISTRIK  ,Alat Praktek SMK TEKNIK INSTALASI TENAGA LISTRIK  2018,jual alat peraga smk,grosir alat praktek smk,produksi alat praktek smk 2018,dak smk 2018,dak smk 2019
Untuk pemesanan atau informasi silahkan hubungi alamat kontak kami :
CV.ASAKA PRIMA | DUTA MEDIA GROUP.
PERCETAKAN & DISTRIBUTOR ALAT LAB & PERAGA PENDIDIKAN.
Jl.Maulana Hasanudin No.52 Cipondoh - Kota Tangerang
Cabang : Ruko Pondok Permata No.1, Jl. Raya Tanggul, Rajeg Mulya, Rajeg, Tangerang, Banten 15540
021 5570 1397
021 5570 2265
0813.1019.7873
WA.0812.1236.8589
WA.0877.7432.4146
0813.8053.7399
www.asakaprima.net
asakaprima@gmail.com